Hitachi.comHitachi.us 
Hard disk drives
 
   
Travelstar LP
Electrical interface specifications

Models:  DBOA-2360, 2528, 2540, 2720
  
IDE signal connector
IDE signal connector
Notes:
  1. Pin position 20 is blank.
  2. Pin position 47 through 50 are used for drive address setting.
 
Signal definition

The pin assignments of interface signals are listed as follows:
 
PIN  Signal       I/O         PIN  Signal       I/O
 01  -HRESET       I           02   GND
 03   HD07        I/O          04   HD08        I/O
 05   HD06        I/O          06   HD09        I/O
 07   HD05        I/O          08   HD10        I/O
 09   HD04        I/O          10   HD11        I/O
 11   HD03        I/O          12   HD12        I/O
 13   HD02        I/O          14   HD13        I/O
 15   HD01        I/O          16   HD14        I/O
 17   HD00        I/O          18   HD15        I/O
 19   GND                     (20)  Key
 21   DMARQ                    22   GND
 23  -HIOW         I           24   GND
 25  -HIOR         I           26   GND
 27   IORDY        O           28   CSEL         I
 29   DMACK                    30   GND
 31   HIRQ         O           32  -HIOCS16      O
 33   HA01         I           34  -PDIAG       I/O
 35   HA00         I           36   HA02         I
 37  -HCSO         I           38  -HCS1         I
 39  -DASP        I/O          40   GND
 41  +5V Logic    PWR          42  +5V Motor    PWR
 43   GND                      44   (Resv)
Notes:
"O" designates an output from the drive.
"I" designates an input to the drive.
"I/O" designates an input/output common.
"PWR" designates a power supply to the drive.
"(Resv)" designates reserved pins which must be left unconnected.
 
+5 volt power supply

There are two input pins for +5 V power supply, "+5V logic" and "+5V motor". "+5V logic" is connected to the internal logic circuits and "+5V motor" is connected to the spindle motor and motor driver.

It is possible to turn on and off "+5V logic" by an external switch circuit to reduce power consumption to the least possible. In this mode, a voltage drop out due to the motor spin up current can be reduced by connecting "+5V motor" line into the system power source directly.

 




   Terms of Use | Privacy Policy | Contact Us