Product description

Models: DCAA-33610, 34330

Features
 
  • PIO and DMA data transfer modes
  • 96 KB adaptive sector buffer
  • Industry standard mounting
  • Advanced ECC on the fly (EOF)
  • CHS and LBA addressing modes
  • Power saving modes
  • Robust design for EMC/RFI
  • MR (magneto resistive) head technology
  • No ID sector format
  • S.M.A.R.T. function support

 

Operating environment
Operating conditions
Temperature 5 to 55 degrees C*
Relative humidity 8 to 90% non-condensing
Maximum wet bulb
temperature
29.4 degrees C non-condensing
Gradient maximum
temperature
15 degrees C/hour
Altitude -300 to 3,048 m
Non operating conditions
Temperature -40 to 65 degrees C
Relative humidity 5 to 95% non-condensing
Maximum wet bulb
temperature
35 degrees C non-condensing
Altitude -300 to 12,000 m
 
* The system is responsible to provide sufficient air movement to maintain surface temperature below 60 degrees C at the center of the top cover of the drive.
 
Operating shock

The hard disk drive meets the following criteria while operating in respective conditions described below. There must be a delay between shock pulses, long enough to allow the drive to complete all necessary error recovery procedures.
 
No errors 5 G, 11 ms half-sine shock pulse
No data loss, seek errors or permanent damage 10 G, 11 ms half-sine shock pulse
No data loss or permanent damage 15 G, 5 ms half-sine shock pulse
30 G, 4 ms half-sine shock pulse
 
Non operating shock

The drive withstands without damage or degradation of performance, a 75 G half-sine wave shock pulse of 11 ms duration on six sides when heads are parked. (When power is not applied to the unit the heads are automatically located in the parked position). Above specification is for shocks applied in each direction of the drives three mutually perpendicular axis, one axis at a time.
 
Operating vibration

Due to the complexity of this subject we recommend that users contact support to discuss how to perform the necessary measurements if they believe this to be an area which requires evaluation.
 
DC power requirement

The following voltage specifications apply at the drive power connector. Damage to the drive electronics may result if the power supply cable is connected or disconnected while power is being applied to the drive (no hot plug/unplug is allowed). There is no special power on/off sequencing required.

Input voltage
 
+5 volts supply 5V (+/-5% during run and spin up) *1
+12 volts supply 12V (+10% -8% during run and spin up) *2

Notes:
  1. To avoid damage to the file electonics 5V, power supply voltage spikes must not exceed 7V.
  2. To avoid damages to the file electronics 12V, power supply voltage spikes must not exceed 15V.
 