DK2xx models: DK23EA-30, DK23EA-40,
DK23EA-60
DK2xx models: DK23EB-40
When the drive is connected to the host bus, a
Master/Slave setting is necessary to configure
a drive as master or slave.
The Master/Slave setting is established between
drives on the interface connector by using jumper
0-2 (pin #A, B, D)
The master drive is assigned to drive address
0, and the slave drive is assigned to drive address
1.
(1) Master(or single) : If all of pins A, B, D
are open, the drive is a Master (Drive Address
0 or single).
 |
<-- interface
connector |
| <-- PCB(Printed
Circuit Board) |
| (View from Interface
Connector) |
|
(2) Slave : If jumper position A-B(marked ) is used, the drive is a
slave (Drive Address 1).
 |
<-- interface
connector |
| <-- PCB(Printed
Circuit Board) |
| (View from Interface
Connector) |
|
(3) CSEL Selection : If jumper position B-D(marked ) is used, Master/Slave setting
is determined by the condition of CSEL signal
(Pin #28).
 |
<-- interface
connector |
| <-- PCB(Printed
Circuit Board) |
| (View from Interface
Connector) |
|
Recommended type of jumper socket
Vender: KYOCERA ELCO CORPORATION
Vender Part Number: 20-8387-002-005-801 or Equivalent
|