DK312C Jumper Plug Installation
The following jumpers are accessible to the user.
Jumper
Pin No.
SCSI ID setting jumper
JP114
J6
9-14
1-6
SCSI bus parity jumper
JP114
15-16
Terminator power on/off
JP121
1-4
WRITE PROTECT setting jumper
J6
9-10
MOTOR START/STOP setting jumper
JP114
3-4
Look ahead cache function setting jumper
JP114
1-2
Look ahead cache function segment setting jumper
JP126
1-6
SCSI ID POLARITY INVERTED setting jumper
J6
7-8
Note 1)
The DK312C jumpers other than listed above (Black Jumper) are installed by the manufacturer and must not be replaced by the user.
Never remove any of the "BLACK" factory set jumpers.
These jumpers are unique to each drive.
All jumpers should be set with power off.
Jumper Plug Location
Fig. 2.2 Jumper Plug Installtion
Note 1)
: Jumper installed
: User changeable
Note 2)
The terminator (TM117) of the DK312C other than the last drive of SCSI Daisy Chain must be removed.