Hitachi.comHitachi.us 
Hard disk drives
 
   
DK325C Jumper Plug Installation
The following jumpers are accessible to the user
Jumper Pin No.
SCSI ID setting jumper J6 1-6
SCSI BUS PARITY CHECK setting jumper JP2 7-8
Terminator power source selecting jumper JP3 1-4
Terminator Enable/Disable setting jumper JP3 5-6
MOTOR START/STOP setting jumper JP2 5-6
Synchronized Spindle jumper JP2 1-4
Synchronized Spindle Terminator jumper JP3 7-8
Note 1)
The DK325C jumpers other than listed above (Black Jumper) are installed by the manufacturer and must not be replaced by the user.
Never remove any of the "BLACK" factory set jumpers.
These jumpers are unique to each drive.
All jumpers should be set with power off.
-jumper socket part numbers.("GREEN")
Name Manufacturer Part No.
Microbit
header
Elco
International K.K.
20-8387-002-005
Note 2)
By using an extension cable from J6 connector, SCSI ID Setting and LED are externally available.
-Connector part numbers on the cable side.
Name Manufacturer Part No.
J6
Connector
Housing Elco
International K.K
62-8387-008-100-001
Contact socket 72-8387-999-100-800
JUMPER SOCKET LAYOUT

(Note 1)
:Jumper installed (at the shipment) :User changeable(GREEN)
(Note 2)
Don't remove any "BLACK" jumpers. (factory setting)