skip header   hitachi.com   hitachi.us    Global
Hitachi Global Storage Technologies
 
DK326C Jumper Plug Installation
DK326C-10/6 (Single Ended Type)

The following jumpers are accessible to the user

Jumper Pin No.
SCSI ID setting jumper J6 1-6
SCSI BUS PARITY CHECK setting jumper JP2 7-8
Terminator power source selecting jumper JP3 1-4
Terminator Enable/Disable setting jumper JP3 5-6
MOTOR START/STOP setting jumper JP2 5-6
Synchronized Spindle jumper JP2 1-4
Synchronized Spindle Terminator jumper JP3 7-8
Note 1)
The DK326C jumpers other than listed above (Black Jumper) are installed by the manufacturer and must not be replaced by the user.
Never remove any of the "BLACK" factory set jumpers.
These jumpers are unique to each drive.
All jumpers should be set with power off.
-jumper socket part numbers.("GREEN")
Name Manufacturer Part No.
Microbit
header
Elco
International K.K.
20-8387-002-005
JUMPER SOCKET LAYOUT (Single Ended Type)
(Note 1)
:Jumper installed (at the shipment) :User changeable(GREEN)
(Note 2)
Don't remove any "BLACK" jumpers. (factory setting)
 





  Terms of Use | Privacy Policy | Contact Us  © 2008 Hitachi Global Storage Technologies