DK326C Jumper Plug Installation
DK326C-10WD Jumper Plug Installation
Delay Motor Start jumper (JP2 1,2) (Wide Differential Type)
(NOTE 1) :jumper installed
| No. |
JP2 1,2 |
Meaning |
| 1 |
 |
|
Install the jumper plugs for JP2 1,2 |
|
Delay motor start up at the power on. |
| 2 |
 |
|
Remove the jumper plugs for JP2 1,2 |
|
Spindle motor start up at the power on. (DEFAULT) |
Note: Terminator is not mounted on DK326C-10WD (Wide Differential
Type)
JUMPER SOCKET LAYOUT
|