Hitachi.comHitachi.us 
Hard disk drives
 
   
DK328H-43/DK318H-91 Jumper socket installation
Delayed Spindle start setting jumper (JP2 1-2)
(Wide single ended Type)

This jumper connector is active only when JP3 7-8 is removed.

No. JP2 Meaning
1
remove the jumper socket for JP2 1,2
(Default)
Spindle motor automatically starts when the power is on.
2
install the jumper socket for JP2 1,2
Spindle motor starts in sequence via ID number x 10 seconds from the time power is applied.
Note1
In the case of WIDE single-ended type, this time is as follows:
ID number 0-7: ID number x 10sec
ID number 8-15: (ID number-8) x 10sec

In the Delayed Spindle Start mode, the start time of each drive is same as the time for WIDE single-ended model.(See Note 1.)

Jumper Connector Layout




   Terms of Use | Privacy Policy | Contact Us