Jumper socket installation
| |
|
Models: DK32EJ-14/72/36FC
SCA-2 Fibre Channel 40pin
Jumper Connector Layout (SCA-2 Fibre
Channel 40pin)
| Pin
No |
1-2 |
3-4 |
5-6 |
7-8 |
9-10 |
11-12 |
| Function |
Reserved |
Reserved |
FLTLED |
Reserved |
Reserved |
Reserved |
| Pin
No |
13-14 |
15-16 |
17-18 |
19-20 |
21-22 |
23-24 |
| Function |
Reserved |
Write
Protect |
Reserved |
Reserved |
ACTLED |
Reserved |
- Black jumper
sockets are used for Use's selection.
They are shown with thick line in the
figure of drive connector.
- Shaded jumper
sockets are default setting at the factory.
- Do not change
the Reserved jumper sockets. Change
will void the warranty!
- Do not connect
the assigned signals pins each other.
If connectcted, it may cause drive failure.
- Spare Jumpers
installed C3: 18-20 for FC model.
These spare jumpers can be used for
another setting.
|
| Installation Tips: |
- Installation horizontal or vertical.(6
direction)
- Provide adequate air flow to cool
drive
- Use 4 mounting screws[6X32 UNC].
Maximum screw penetration:3.8mm(0.15in)into
drive.
|
|
|
|
 |
 |
|
|
|
|
|
|