Jumper socket installation
| |
|
Models: DK32EJ-14/72/36NW
Wide LVD 68pin-16bits
Jumper Connector Layout (Wide LVD 68pin-16bits)
| Pin
No |
1-2 |
3-4 |
5-6 |
7-8 |
9-10 |
11-12 |
| Function |
ID3 |
ID2 |
ID1 |
ID0 |
Disable
Auto Start |
Force
SE bus mode |
| Pin
No |
13-14 |
15-16 |
17-18 |
19-20 |
21-22 |
23-24 |
| Function |
Enable
Delayed Start |
Write
Protect |
Reserved |
Reserved |
LED(with
0ohm) |
Term.
Power |
- Black jumper sockets
are used for Use's selection.
They are shown with thick line in the
figure of drive connector.
- Shaded jumper sockets
are default setting at the factory.
- Do not change the
Reserved jumper sockets. Change will
void the warranty!
- Do not connect the
assigned signals pins each other.
If connectcted, it may cause drive failure.
- Spare Jumpers installed
C3: 2-4, 6-8, 10-12, 14-16, 18-20 for
NW model.
These spare jumpers can be used for
another setting.
|
| Installation Tips: |
- Installation horizontal or vertical.(6
direction)
- Provide adequate air flow to cool
drive
- Use 4 mounting screws[6X32 UNC].
Maximum screw penetration:3.8mm(0.15in)into
drive.
|
|
|
|
 |
 |
|
|
|
|
|
|