DK512A Jumper Plug Installation  

The following jumpers are accessible to the user.

Selecting Sector/Address Mark Found JP146 9-10
Selecting Bytes/Sector and Sectors/Track JP285 9-10
Selecting Drives JP148 1-6
Setting Device Type JP148 7-10
Setting/Resetting WRITE PROTECTED JP101 1-4
Setting Motor Start/Stop Option JP146 11-12
Installing Termination Networks
The termination networks terminate the control signals line (J1). As shipped, one termination network is installed in each drive. Figure 3-1 shows the location.
  • In star (radial) systems, leave the termination networks in all drives.
  • In daisy-chain systems, remove the termination networks from all drives except the drive at the end of the daisy-chain.

LED is lit if the drive is selected and READY
Figure 3-1 Jumper Plugs, LED and Network on PC Assembly SZ204