skip header   hitachi.com   hitachi.us    Global
Hitachi Global Storage Technologies
 
DK514C Jumper Plug Installation
 Motor Start/Stop option jumper

Table 2-3 Motor Start/Stop option

No. Jumper plug JP257 bit 2^0 Meaning
1 The motor start/stop option not is selected. The spindle motor is started when DK514C power is turned on. (Note)
2 The motor start/stop option is selected. The spindle motor can be started or stopped by using SCSI command.

As shipped from the manufacture, this jumper is installed in position#1 (option not selected).
When the motor start/stop option (No.2) is selected, the drive enters the motor stop state when its power is turned on.
Use the Start/Stop Unit (1BH) command to start or stop the drive.

(Note)
When motor start/stop option is not used, the controller does not respond to the host about 35 sec from power turn-on to Drive Ready.

:User changeable, other than them are inhibited to change.

JUMPER SOCKET LAYOUT
 
 






  Terms of Use | Privacy Policy | Contact Us  © 2008 Hitachi Global Storage Technologies