skip header   hitachi.com   hitachi.us    Global
Hitachi Global Storage Technologies
 
DK514S-38D/38S Jumper Plug Installation
 TAG4 and TAG5 Modes A,B and C Jumper plugs

1. For DK514S-38S, set by JP174 (pin 9-12) or JP179 (pin 9-12) on the SZ906 PCB.
SZ906 PCB Rev.0 Jumper Location
SZ906 PCB Rev.1 Jumper Location

Mode A B C
PCB Rev.0
JP174
(pin9-12)
or
PCB Rev.1
JP179
(pin9-12)
 
TAG4 Don't care FALSE TRUE FALSE TRUE FALSE TRUE
TAG5 *1 *1 *1 FALSE FALSE TRUE TRUE
STATUS 0 UNIT READY UNIT READY SECTOR ADDRESS 1 UNIT READY SECTOR ADDRESS 1 STATUS ERROR 1 DEVICE TYPE 1
STATUS 1 ON CYLINDER ON CYLINDER SECTOR ADDRESS 2 ON CYLINDER SECTOR ADDRESS 2 STATUS ERROR 2 DEVICE TYPE 2
STATUS 2 SEEK ERROR SEEK ERROR SECTOR ADDRESS 4 SEEK ERROR SECTOR ADDRESS 4 WRITE ERROR 1 DEVICE TYPE 4
STATUS 3 FAULT FAULT SECTOR ADDRESS 8 FAULT SECTOR ADDRESS 8 WRITE ERROR 2 DEVICE TYPE 8
STATUS 4 WRITE PROTECTED WRITE PROTECTED SECTOR ADDRESS 16 WRITE PROTECTED SECTOR ADDRESS 16 WRITE ERROR 3 DEVICE TYPE 16
STATUS 5 ADDRESS MARK FOUND ADDRESS MARK FOUND SECTOR ADDRESS 32 ADDRESS MARK FOUND SECTOR ADDRESS 32 SELECT ERROR 1 DEVICE TYPE 32

Fig. 2-6A TAG4 and TAG5 Modes A,B and C Jumper plugs for DK514S-38S

*1 In case of no installed jumper plug at JP174 pin 9-10 or JP179 pin 9-10, unit select 2^3/TAG5 lines are available to unit select 2^3.

Notes : As shipped, jumper plug is installed for Mode C.


2. For DK514S-38D, set by JP174 (pin 9-12) or JP179 (pin 9-12) on the SZ906 PCB and JP85 (pin 11-12) on the SZ241 PCB.
SZ241 PCB Rev.0 Jumper Location
SZ241 PCB Rev.1 Jumper Location

Mode A B C
PCB Rev.0
JP174
(pin9-12)
or
PCB Rev.1
JP179
(pin9-12)
SZ241
JP85
(pin11-12)
or
TAG4 Don't care FALSE TRUE FALSE TRUE FALSE TRUE
TAG5 *1 *1 *1 FALSE FALSE TRUE TRUE
STATUS 0 UNIT READY UNIT READY SECTOR ADDRESS 1 UNIT READY SECTOR ADDRESS 1 STATUS ERROR 1 DEVICE TYPE 1
STATUS 1 ON CYLINDER ON CYLINDER SECTOR ADDRESS 2 ON CYLINDER SECTOR ADDRESS 2 STATUS ERROR 2 DEVICE TYPE 2
STATUS 2 SEEK ERROR SEEK ERROR SECTOR ADDRESS 4 SEEK ERROR SECTOR ADDRESS 4 WRITE ERROR 1 DEVICE TYPE 4
STATUS 3 FAULT FAULT SECTOR ADDRESS 8 FAULT SECTOR ADDRESS 8 WRITE ERROR 2 DEVICE TYPE 8
STATUS 4 WRITE PROTECTED WRITE PROTECTED SECTOR ADDRESS 16 WRITE PROTECTED SECTOR ADDRESS 16 WRITE ERROR 3 DEVICE TYPE 16
STATUS 5 ADDRESS MARK FOUND ADDRESS MARK FOUND SECTOR ADDRESS 32 ADDRESS MARK FOUND SECTOR ADDRESS 32 SELECT ERROR 1 DEVICE TYPE 32

Fig. 2-6B TAG4 and TAG5 Modes A,B and C Jumper plugs for DK514S-38D

*1. In case of no installed jumper plug at JP85 pin 11-12, on SZ241 PCB, unit select 2^3/TAG5 lines are available to unit select 2^3.

Notes : As shipped, jumper plug is installed for Mode C.

 