DK515C Jumper Plug Installation
Motor Start/Stop option jumper
Table 2-3 Motor Start/Stop option
| No. |
Jumper plug JP223
bit 2^3 |
Meaning |
| 1 |
 |
The motor start/stop option not is selected.
The spindle motor is started when power is turned on.(Note) |
| 2 |
 |
The motor start/stop option is selected. The
spindle motor can be started or stopped by using SCSI command. |
As shipped from the manufacture, this jumper is installed in position#1
(option not selected)
When the motor start/stop option (No.2) is selected, the drive
motor state depends on Motor Auto Start option (Table2-4) when its
power is turned on.
Use the start/stop Unit (1BH) command to start or stop the drive.
- (Note)
- The controller does not respond to the host about 500ms from
Power turn-on.
: User changeable, other
than them are inhibited to change.
Jumper Location
|