skip header   hitachi.com   hitachi.us    Global
Hitachi Global Storage Technologies
 
DK515C Jumper Plug Installation
Motor Start/Stop option jumper

Table 2-3 Motor Start/Stop option

No. Jumper plug JP223
bit 2^3
Meaning
1 The motor start/stop option not is selected. The spindle motor is started when power is turned on.(Note)
2 The motor start/stop option is selected. The spindle motor can be started or stopped by using SCSI command.

As shipped from the manufacture, this jumper is installed in position#1 (option not selected)

When the motor start/stop option (No.2) is selected, the drive motor state depends on Motor Auto Start option (Table2-4) when its power is turned on.
Use the start/stop Unit (1BH) command to start or stop the drive.

(Note)
The controller does not respond to the host about 500ms from Power turn-on.

: User changeable, other than them are inhibited to change.