DK516 Jumper Plug Installation
Setting of Terminator Module and Terminator Switches
- Control Signal
- Each drive in Radial connection of cable B and the last end
of the drives in Daisy Chain connection of cable B should be terminated.
Since a terminator module (TM) and Terminator Switch I (JP4) are
provided to all drives as shipped, remove all of them except the
last drive in case of Daisy Chain connection .
Table 2-1 Terminator Module and Terminator Switch I
| Configuration |
Terminator
Module (TM) |
Terminator Switch I
(JP4, pin 1-6) |
-Single drive on cable B
-All drive in Radial connection
-The last drive in Daisy Chain (Factory Default) |
 |
 |
| -All drives except the last one in Daisy
Chain |
 |
 |
* At the time of shipment, Terminator Module and Terminator Switch
I are mounted on Terminator socket.
- Synchronized Spindle Signal
- Synchronized Spindle Signal is terminated via JP5 to terminator
resistor on the PCB. When the synchronized spindle option is used,
JP5 shall be removed except the last drive in Daisy Chain OF Synchronized.
Table 2-2 Terminator Switch II
| Configuration |
Terminator Switch II (JP5) |
| The last Slave drive (Factory Default) |
 |
| All drives except the last Slave drive |
 |
* A drive as shipped is mounted with Terminator Switch II
Jumper Location
|
|
|