Hitachi.comHitachi.us 
Hard disk drives
 
   
DK522C Jumper Plug Installation

The following jumpers are accessible to the user (use green jumper plugs) :

Jumper Bit
SCSI ID setting jumper JP204 2^0-2^2
SCSI bus parity jumper JP204 2^3
Terminator power on/off JP102 2^0
Write protect jumper JP290 2^0
Motor Start/Stop jumper JP186 2^4
(Note)
The DK522C jumpers other than listed above are installed by the manufacturer and must not be replaced by the user (black jumper plugs).

(Application PCB Rev.4,5,6) Note : Rev.6 is not shipped.

Fig. 2-7-1 SZ903 PCB Jumper Locations (at the shipment)

Note:
*1) The terminator of the DK522C other than the last drive of SCSI Daisy Chain must be removed.
*2) : Jumper installed : User changeable (Green Jumper)
* Other than them are inhibited to change
(Application PCB Rev.7-)

Fig. 2-7-2 SZ903 PCB Jumper Locations (at the shipment)

Note:
*1) The terminator of the DK522C other than the last drive of SCSI Daisy Chain must be removed.
*2) : Jumper installed : User changeable (Green Jumper)
* Other than them are inhibited to change