skip header   hitachi.com   hitachi.us    Global
Hitachi Global Storage Technologies
 
Ultrastar 36LP
Jumper settings

Model: DPSS-336950, 318350, 309170

Ultrastar 36LP models have two jumper blocks, J4 and J6, which are located on the logic card as shown below.  68-pin models also have an auxiliary connector.  A detailed description of the jumper signals is available in the functional specifications.

See the following topic for additional installation information:

Installation notes for LVD drives

J4 and J6 jumper block locations

J4 and J6 jumper block locations

 

J4 option jumper block

J4 option jumper block

J6 option jumper block

J6 option jumper block

68-pin auxiliary connector

The 68 pin models have an auxiliary connector between the power connector and the 68-pin SCSI connector that replicates some of the functions contained in the J4 and J6 option jumper blocks.  Either the option jumper blocks (J4 and J6) or the 68-pin auxiliary connector can be used but do not use both.

68 pin auxiliary connector

SCSI address settings

The SCSI address of the drive is specified by installing jumpers on Jumper block J4 pins 7 and 8 (ID bit 0), 9 and 10 (ID bit 1), 11 and 12 (ID bit 2), and 13 and 14 (ID bit 3).  The auxiliary connector can also be used to specify the SCSI address for the drive.

Notes:

  1. SCSI address 0 is the shipping default for 80-pin models.
  2. SCSI address 6 is the shipping default for 68-pin models.